溢流閥 排渣閥 卸料閥 平衡閥 管夾閥 蝶閥 球閥 截止閥 閘閥 柱塞閥 控制閥 燃?xì)忾y 安全閥 針型閥 隔膜閥
常州竹簀閥門有限公司
參 考 價 | 面議 |
產(chǎn)品型號VPF
品 牌
廠商性質(zhì)經(jīng)銷商
所 在 地常州市
聯(lián)系方式:葉明花查看聯(lián)系方式
更新時間:2016-05-16 14:47:57瀏覽次數(shù):329次
聯(lián)系我時,請告知來自 泵閥商務(wù)網(wǎng)暫無信息 |
動態(tài)平衡電動二通閥/電動平衡調(diào)節(jié)閥/電動平衡閥關(guān)斷力6.8Bar寬壓差范圍內(nèi)盤管水流量精度自動恒定模數(shù)化流量工廠標(biāo)定,無需現(xiàn)場平衡調(diào)試。電動執(zhí)行器低噪運(yùn)轉(zhuǎn),安裝及拆卸十分方便電動執(zhí)行器僅在動作時間15秒內(nèi)耗電4VA,在全開或全關(guān)位置時機(jī)械鎖定真正零耗電一體化動態(tài)平衡電動二通閥明顯降低水系統(tǒng)流動噪聲,*解決水力平衡問題,綜合節(jié)能效果6%-35%。
動態(tài)平衡電動二通閥安裝說明 . 安裝前請仔細(xì)閱讀產(chǎn)品說明書,核對產(chǎn)品型號。 . 水流方向必須按照閥體上指示得方向相同。 3. 在用于風(fēng)盤或空氣處理機(jī)組管路時,閥體須位于接水盤上方,以保證出現(xiàn)滴水時落 入接水盤中。 4. 閥體及執(zhí)行器安裝于垂直方向±60范圍內(nèi),其上方應(yīng)至少有30mm空間用于拆裝。 與周圍管道、設(shè)備、建筑物必須保持足夠的維修操作空間,必須安裝在維修人員通 過檢修孔能觸及到的地方。 5. 閥體安裝完畢并與管路通過試壓后才可安裝執(zhí)行器。閥前需裝過濾器。 6. 所有接線需遵守國家和地方電氣規(guī)范,執(zhí)行器須避免受潮。 Instructions . Read the instructions carefully, check the product model before installation. . Flow direction must be identical with the direction on the valve body. 3. When used on a pipeline of fan coil or air handling units, valves shall be located above the water tray to ensure the possible drop fall into the tray. 4. The valve and actuator are recommended to be mounted within ±60 degrees of the upright position. Above it there should be at least 30mm space for assembly and disassembly. The valve and actuator must be installed with suf?cient operating space around pipelines, equipment and buildings, and where maintenance worker can touch through the access hole. 5. The actuator can only be installed after the valve installed and pressure tested. Strainer is required before the valve. 6. All wiring must comply with local, regional, and national electrical code requirements. The actuator housing must be protected from moisture. 安裝方向/Installation direction Instructions . Read the instructions carefully, check the product model before installation. . Flow direction must be identical with the direction on the valve body. 3. When used on a pipeline of fan coil or air handling units, valves shall be located above the water tray to ensure the possible drop fall into the tray. 4. The valve and actuator are recommended to be mounted within ±60 degrees of the upright position. Above it there should be at least 30mm space for assembly and disassembly. The valve and actuator must be installed with suf?cient operating space around pipelines, equipment and buildings, and where maintenance worker can touch through the access hole. 5. The actuator can only be installed after the valve installed and pressure tested. Strainer is required before the valve. 6. All wiring must comply with local, regional, and national electrical code requirements. The actuator housing must be protected from moisture. |
您感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN
西安RS485/M-BUS通訊海林遠(yuǎn)傳超聲波熱量表
HU ¥999山東電動籠式調(diào)節(jié)閥 濟(jì)南電動籠式調(diào)節(jié)閥
電動籠式調(diào)節(jié)閥 面議泵閥商務(wù)網(wǎng) 設(shè)計制作,未經(jīng)允許翻錄必究 .? ? ?
請輸入賬號
請輸入密碼
請輸驗證碼
請輸入你感興趣的產(chǎn)品
請簡單描述您的需求
請選擇省份
聯(lián)系方式
常州竹簀閥門有限公司