廣泛應(yīng)用于冷熱水系統(tǒng),用于對(duì)整個(gè)循環(huán)系統(tǒng)進(jìn)行精確的水力平衡控制,以達(dá)到節(jié)能、提高效率的目的。采用內(nèi)置孔板測(cè)量流量,流量測(cè) 量精度+/-5%。閥門(mén)根據(jù) BS7350標(biāo)準(zhǔn)。
蒸汽江森靜態(tài)平衡閥滬工閥門(mén) 上海良工 開(kāi)維喜閥門(mén) 上海閥門(mén)廠(chǎng)家,DN1 - 0
特點(diǎn) Y型設(shè)計(jì)靜態(tài)平衡閥具有優(yōu)秀的調(diào)節(jié)和截止功能,其流量特性曲線(xiàn)為等百分比特 性。擁有內(nèi)置測(cè)量孔板和測(cè)量接頭。可通過(guò)調(diào)節(jié)手輪來(lái)準(zhǔn)確調(diào)節(jié)流量,擁有精確
到1/10圈的位置指示。江森自控閥門(mén)從全開(kāi)到全關(guān)需要 整圈。轉(zhuǎn)動(dòng)手輪,指示器顯示開(kāi) 度情況。實(shí)測(cè)壓差與流量關(guān)系不會(huì)隨著手輪開(kāi)度變化。
蒸汽江森靜態(tài)平衡閥滬工閥門(mén) 上海良工 開(kāi)維喜閥門(mén) 上海閥門(mén)廠(chǎng)家,DN - 00
特點(diǎn)Y型設(shè)計(jì)江森靜態(tài)平衡閥具有優(yōu)秀的調(diào)節(jié)和截止功能,其流量特性曲線(xiàn)為等百分比特 性。擁有內(nèi)置測(cè)量孔板和測(cè)量接頭。通過(guò)調(diào)節(jié)手輪以達(dá)到要求的流量。開(kāi)度指示
器顯示zui終的閥門(mén)設(shè)置。壓差與流量之間的關(guān)系不會(huì)隨著手輪的設(shè)置而變動(dòng)。 從全開(kāi)到全關(guān),DN -1 0需要 整圈,DN200-2 0需要12整圈,DN 00需要1 整 圈。基本圈數(shù)和精確到1/10圈的顯示能夠準(zhǔn)確指示開(kāi)度情況。
Application
Static balance is achieved by pre-setting of opening position,which could be read by scale on two circles (one for basic circle and another for ?ne adjustable circle). DN 5-50 valves have two pressure testing connectors, while DN65 and above have two plugs on the valves, two testing connectors in the package to be replaced on jobsite. The valves may be installed in either the supply or the return pipe, and normally on the return pipe.
Inspection And Storage
Inspect valves while receiving the valve. Put all valves carefully on the ground. When lifting, the valve should be tightly secured and never lifted by the bronze or stainless steel trim.
The valves should keep clean and dry before installation. If storage period more than six months, the surfaces of the seat (when provided) should be coated with a thin ?lm of FDA approved grease. Do not expose rubber seat to sunlight or ozone.
Installation
The ?ow arrow on the valve must be the same to the ?ow direction in the pipe system.
The valve must be installed in a run of pipe of the same nominal size. All valves are recommended to be installed as ?g below. To ensure ?ow measurement accuracy it
is essential that the piping on the inlet and outlet sides is straight and has a minimum length equivalent to 5 diameters at inlet and 2 diameters at outlet as shown. If the valve is located on the outlet from a pump then it is essential that the straight pipe length between pump outlet and valve inlet is a minimum of 0 diameters.
維修
江森靜態(tài)平衡閥不需要常規(guī)的日常維護(hù)。如果閥桿與壓蘭之間有泄漏,可以擰緊一下壓 蘭填料。拆下手輪鎖母,去掉手輪。按要求擰緊壓蘭螺栓。不要過(guò)度擰緊以免 影響正常操作。(閥門(mén)沒(méi)有上密封功能,不能帶壓去除壓蘭)。重新安裝手 輪,檢查閥門(mén)是否正常操作,是否有泄漏。
Maintenance
No routine maintenance is required. It is possible to tighten the gland while leakage happen between stem and gland Unscrew the hand wheel nut, remove the hand wheel, tighten the gland screw. (The valves are not provided with top sealing. Removing gland without relieving the presssure is prohibited.) Reinstall the hand wheel, check the valve for smooth operating and no leakage.